Surge Suppressors

CITEL Surge Suppressors offer shielded construction and are available in DIN-rail or panel-mount mounting styles. The DLAx suppressors feature hybrid SAD-GDT technology and are UL 497B listed and UL 121201 listed for hazardous locations. The DD9 suppressor is designed for RS networks and supports data rates up to 40Mbps, while the DD15 has low-frequency coaxial surge protection with bidirectional protection and a waterproof design. B180 and B480 suppressors offer 20kA Imax, 5kA Imp, and 5kA specification ratings, and <1dB insertion loss and thermoplastic construction. MJ8-POE suppressors are POE++ compatible and feature a 16kA maximum surge discharge capability, maximum transmission of 10Gbps, and a bandwidth of up to 500MHz. CITEL MSP-VMx protectors are combined POE mid-span injector or splitter and SPD and have an integrated power supply injector connector.

Ergebnisse: 10
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (CHF) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Typ Montageart Montage Nennspannung Nennstrom Minimale Betriebstemperatur Maximale Betriebstemperatur Länge Breite Höhe
Citel Industrielle Überspannungsschutzgeräte DD15-24V D-sub Data Line Surge Protectice Device (SPD) , 24V, 9 wire+G 22Auf Lager
Min.: 1
Mult.: 1

Data Line Panel Mount Screw 40 VDC - 40 C + 85 C 61 mm 30.5 mm
Citel Industrielle Überspannungsschutzgeräte 4-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 12V, screw terminals 4Auf Lager
Min.: 1
Mult.: 1

Signal Line Chassis Mount Screw 12 VDC - 50 C + 85 C 120 mm 60 mm 35 mm
Citel Industrielle Überspannungsschutzgeräte 4-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 24V, screw terminals 13Auf Lager
Min.: 1
Mult.: 1

Signal Line Chassis Mount Screw 28 VDC - 50 C + 85 C 120 mm 60 mm 35 mm
Citel Industrielle Überspannungsschutzgeräte DD9-24V D-sub Data Line Surge Protectice Device (SPD) , 24V, 15 wire+G 1Auf Lager
Min.: 1
Mult.: 1

Data Line Panel Mount Screw 40 VDC 300 mA - 50 C + 85 C 61 mm 40.6 mm
Citel Industrielle Überspannungsschutzgeräte 1-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 24V, screw terminals 44Auf Lager
Min.: 1
Mult.: 1

Signal Line Chassis Mount Screw 28 VDC - 50 C + 85 C 68 mm 60 mm 25 mm
Citel Industrielle Überspannungsschutzgeräte UL497B, Dataline Surge Protective Device (SPD), 12V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated-Class I, Div. 2, Groups A, B, C & D 6Auf Lager
Min.: 1
Mult.: 1

DIN Rail 12 VDC 300 mA - 40 C + 85 C 90 mm 13 mm 65 mm
Citel Industrielle Überspannungsschutzgeräte UL497B/UL121201, Dataline Surge Protective Device (SPD), 24V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated-Class I, Div.2, Groups A, B, C & D 3Auf Lager
Min.: 1
Mult.: 1

DIN Rail 24 V 300 mA - 35 C + 85 C 90 mm 13 mm 65 mm
Citel Industrielle Überspannungsschutzgeräte 1-Pair Surface Mount Signal Line Surge Protective Device (SPD), Indoor, 12V, screw terminals Nicht auf Lager
Min.: 1
Mult.: 1

Signal Line Chassis Mount Screw 12 VDC 300 mA - 50 C + 85 C 68 mm 60 mm 25 mm
Citel Industrielle Überspannungsschutzgeräte UL497B, Dataline Surge Protectice Device (SPD), 6V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated- Class 1, Div. 2, Groups A, B, C & D Nicht auf Lager
Min.: 8
Mult.: 8

DIN Rail Screw 6 VDC 300 mA - 40 C + 85 C 90 mm 13 mm 65 mm
Citel Industrielle Überspannungsschutzgeräte UL497B/UL121201 , Dataline Surge Protective Device (SPD), 48V, Imax 20kA, In 5kA, 1-pair, Dedicated Shield, Ground protection, Replaceable Module-Hazardous Location Rated- Class I, Div. 2, Groups A, B, C & D Nicht auf Lager
Min.: 8
Mult.: 8

DIN Rail Screw 48 VDC 300 mA - 35 C + 85 C 90 mm 13 mm 65 mm