14A One-4-All™ International Transformers

Signal Transformer / Bel 14A (One-4-All) PC and Chassis Mount Transformers are specifically designed to satisfy North American (UL, CSA, CE) and international (VDE, IEC, CSA, CE) transformer regulatory requirements for power isolation in Medical and Dental applications. Signal Transformer / Bel 14A ensures double isolation and low leakage current, surpassing the construction requirements for patient-connected equipment per UL 544 Standard for Medical and Dental Equipment, as well as, the IEC 601-1 Standard for Medical Electrical Equipment. The transformers are dielectric strength tested to 4000VRMS, provide a UL class F insulation system, and meet the creepage and clearance requirements for both the UL and IEC standards. The 14A series is available in nine PC mount models with 2.5VA-56VA power.

Ergebnisse: 48
Auswählen Bild Teile-Nr. Herst. Beschreibung Datenblatt Verfügbarkeit Preis (CHF) Ergebnisse in der Tabelle nach dem Einheitspreis bei Ihrer Menge filtern. Menge RoHS ECAD Model Primärnennspannung Sekundärnennspannung Nennleistung Sekundärnennstrom Montageart Primärgewinde Sekundärgewinde Länge Breite Höhe Serie
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 86Auf Lager
100erwartet ab 31.07.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 36 V CT/18 V 20 VA 560 mA/1.12 A Through Hole Dual Primary Winding Dual Secondary Winding 57.2 mm 47.6 mm 41.3 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 16Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 5 V/12 V 20 VA 200 mA/750 mA Through Hole Dual Primary Winding Dual Secondary Winding 57.2 mm 47.6 mm 41.3 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 19Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 20 V CT/10 V 30 VA 1.5 A/3 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 93Auf Lager
500erwartet ab 31.07.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 24 V CT/12 V 30 VA 1.25 A/2.5 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 88Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 36 V CT/18 V 30 VA 820 mA/1.64 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 96Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 5 V/15 V 30 VA 200 mA/1.25 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 1Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 20 V CT/10 V 5 VA 250 mA/500 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 34.9 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 98Auf Lager
100erwartet ab 03.07.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 28 V CT/14 V 5 VA 180 mA/360 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 34.9 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 3Auf Lager
300erwartet ab 21.10.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 36 V CT/18 V 5 VA 140 mA/280 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 34.9 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 14Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 10 V CT/5 V 56 VA 5.6 A/11.2 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 25Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 24 V CT/12 V 56 VA 2.33 A/4.66 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 42Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 16 V CT/8 V 2.5 VA 150 mA/300 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 28.6 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer 47Auf Lager
Min.: 1
Mult.: 1

115 VAC, 230 VAC 16 V CT/8 V 30 VA 1.9 A/3.8 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer
500erwartet ab 31.07.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 28 V CT/14 V 30 VA 1.06 A/2.12 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer
200erwartet ab 31.07.2026
Min.: 1
Mult.: 1

115 VAC, 230 VAC 12.6 V CT/6.3 V 5 VA 400 mA/800 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 34.9 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1

115 VAC, 230 VAC 28 V CT/14 V 2.5 VA 90 mA/180 mA Through Hole Dual Primary Winding Dual Secondary Winding 41.3 mm 36.5 mm 28.6 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 75
Mult.: 25

115 VAC, 230 VAC 10 V CT/5 V 20 VA 2 A/4 A Through Hole Dual Primary Winding Dual Secondary Winding 57.2 mm 47.6 mm 41.3 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 500
Mult.: 20

115 VAC, 230 VAC 10 V CT/5 V 30 VA 3 A/6 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1

115 VAC, 230 VAC 12.6 V CT/6.3 V 30 VA 2.4 A/4.8 A Through Hole Dual Primary Winding Dual Secondary Winding 66.7 mm 55.5 mm 39.7 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1

115 VAC, 230 VAC 16 V CT/8 V 56 VA 3.5 A/7 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1

115 VAC, 230 VAC 20 V CT/10 V 56 VA 2.8 A/5.6 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 1
Mult.: 1

115 VAC, 230 VAC 36 V CT/18 V 56 VA 1.56 A/3.12 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A
Bel Signal Transformer Leistungstransformatoren - Boardmontage 50\60 Hz, Laminated Transformer Nicht-auf-Lager-Vorlaufzeit 18 Wochen
Min.: 40
Mult.: 20

115 VAC, 230 VAC 5 V/12 V 56 VA 300 mA/3 A Through Hole Dual Primary Winding Dual Secondary Winding 76.2 mm 63.5 mm 46.5 mm 14A